Database Hardware Discussion

Effective memory access time:

EA = HC + (1-H)S
Where H = Hit ratio
Hit ratio = references satisfied by cache / total references
C = cache access time; S = memory access time

Effective disk buffer cache access time:

EA = HC + (1-H)S
Where H=Hit ratio C = cache access time; S = memory access time
Disk access time = seek time (tracks)+ rotational time (section) + transferlength / bandwidth

Storage System

  • MTBF (Mean Time Between Failure):
    Describes the expected time between two failures for a repairable system

    • Time between failures = {down time - up time}
    • C12pture.PNG
  • Mean Time to Repair
    (Total down time) / (number of breakdowns)

  • Mean Time to Fail:
    For the product that cannot be repaired.

RAID (Redundant Array of Independent)

  • RAID 0

ure.PNG
  • Block Level Striping(4k or 8k bytes of storage)

  • Provides balanced I/O of disk, throughput approximately doubles

  • Any one of the disk failure could cause the MTTF reduces by a factor of 2

  • RAID 1

Capddure.PNG
  • Block Level Mirroring

  • Provides higher read throughput but lower write throughput

  • MTTF increases substantially (MTTF^2)

  • RAID 2

ggture.PNG
  • Bit Level Mirroring(4k or 8k bytes of storage)

  • Provides higher transfer rate

  • MTTF increases substantially (MTTF^2)

  • RAID 3

Cadfure.PNG
  • Byte Level Striping (Parity)

  • Provides higher transfer rate as RAID 0

  • MTTF increases substantially (1/3 of RAID 1 = MTTF^2/3)

  • P0 is parity (exclusive-or) for b0 and b1. Knowing any two of the disk data could recover the third data.

  • RAID 4

Cadture.PNG
  • Block Level Striping (Parity)

  • Similar to RAID 3

  • Disk 3 has a lot more stress because it has more writes than either disk 1 and disk 2 as the parity has to be updated on every write

  • RAID 5

Capture.PNG
  • Block Level Striping (Parity)

  • Single disk failure tolerant array

  • No dedicated disk for parity blocks, parity blocks are also striped

  • MTTF is same as RAID 3


    Capture.PNG
  • RAID 6

  • At least 5 disks including two parity blocks used

  • Reliability is of the order of MTTF^3/10

  • p0 and p1 are the parity blocks for blocks A0,A1,A2

©著作权归作者所有,转载或内容合作请联系作者
平台声明:文章内容(如有图片或视频亦包括在内)由作者上传并发布,文章内容仅代表作者本人观点,简书系信息发布平台,仅提供信息存储服务。